T1E0A10A

T1E0A10A temperature

Temperature sensor, integrated module

  • Range -20 to 100 Deg C
  • Supply 5-10 VDC
  • Output 10 mV/C
  • Accuracy 0.2% full scale
T1E0B10A

T1E0B10A temperature

Temperature measurement module

  • Range -25 to 400 Deg C
  • Supply 6-15 VDC
  • Sensitivity 10 mV/C
  • J or K thermocouples
U1B0B10A

U1B0B10A Voltage Module

Voltage Measurement Module

  • Range +/- 1 kV
  • Output 2.5V
  • Accuracy 0.05% FS
  • High shock resistance
Load More

Frequently Asked Questions About Voltage And Temperature Sensors

Need Help with Voltage And Temperature Sensors?

Learn about our temperature and voltage sensor specifications, measurement capabilities, and customization options for your specific application needs.

Our temperature sensors come in two models: The T1E0A10A, which operates within a temperature range of -20 to 100°C, with a supply voltage of 5-10 VDC and an output of 10 mV/°C, maintaining an accuracy of 0.2% full scale. The T1E0B10A operates from -25 to 400°C, with a supply of 6-15 VDC, also providing an output of 10 mV/°C using J or K type thermocouples for enhanced sensitivity.

The U1B0B10A Voltage Measurement Module is designed for high precision with a measurement range of +/- 1 kV and an output of 2.5V. It is renowned for its high shock resistance and maintains an accuracy of 0.05% FS, ensuring reliable and precise voltage monitoring even in demanding settings.

The temperature sensors convert the measured temperature into a voltage output, where each millivolt represents a change in temperature. For instance, a 10 mV/°C sensitivity means that for every degree Celsius change in temperature, the output changes by 10 millivolts. To find the temperature from the voltage, divide the voltage output by the sensitivity (10 mV/°C).

Yes, our voltage and temperature sensors are highly configurable to meet specific requirements. Clients can request customisations such as cable lengths and other specifications to suit their particular application needs. These are plug-and-play devices, facilitating easy integration into your existing systems.